Indoor Air Quality (IAQ) is measure for the quality of air in interiors, the comfortable indoor environmental quality can make people feel fresh, work efficiency and good for the health. The CO2 concentration is the important factor of good indoor air quality. People breath in oxygen and breath out CO2, nowadays people often close the windows to avoid noise and enjoy the comfort living and working environment provided by air-conditioning systems, which results in the fact that the indoor concentration of CO2 is far higher than outdoor average. With the high CO2 concentration and non- proper ventilation, people will feel headaches, dull, drowsiness, lose of concentration and correspond to the high levels of dust, chemicals and bacteria in the air. |
|
|
|
|
|
|
3 IN 1 CO2 Monitor (CO2+Temp.+RH) Operating Instructions |
|
|
|
|
ZG1583RUD CO2 monitor are smart, compact and easy-to-use. In addition to measuring the CO2 |
|
concentration, they can also measure the ambient temperature and the relative humidity (CO2+Temp. +RH). |
|
These products are developed to detect the presence of CO2 in ambient air and help people to take care of |
Indoor Air Quality. they can be widely used in the office building, school, exhibition hall, shopping mall, meeting |
|
room, fitness center, restaurant and other public places where personal comfort, healthy is important. |
|
|
|
|
|
|
|
|
|
Dual Beam NDIR technology to improve the long term stability |
|
Measure CO2, Temperature and Relative Humidity |
|
3 LED display shows the current Indoor Air Quality |
|
Press “MUTE“ for alarm on/off |
|
Built in the LCD Backlight for easy reading in the dark |
|
Datalog Function: Connect to PC, micro SD card |
|
|
|
|
|
|
|
|
|
|
1. |
Green LED Display |
|
|
(<800ppm) |
|
|
2. |
Yellow LED Display |
|
|
(800-1200ppm) |
|
|
3. |
Red LED Display |
|
|
(>1200ppm) |
|
|
|
|
|
|
|
|
|
|
|
 |
EMC/RFI |
|
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of |
|
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected. |
|
Note: Under the electromagnetic field of 3V/m, the reading will not meet the specification. |
|
|
|
|
|
|
|
|
|
 |
1. After power on, the bars on the LCD are decreasing |
by degrees and keep flashing during warm-up (1 min). |
2. The MUTE button is disabled during warm-up. |
3. The device shows the CO2 reading after warm-up. |
|
|
|
|
|
|
|
|
|
 |
Press MUTE button to select buzzer on/off. If the |
“MUTE” function is off, while CO2 concentration |
exceed the alarm level (>1200 ppm), there will be a buzzer. |
Note: The device setting with alarm is buzzer on when |
power on first time, user can set the alarm on/off under |
|
MUTE function. |
|
|
|
|
|
|
|
|
How to log CO2/Temp./RH data |
|
|
|
Method 1: The device needs to connect with PC always for data logging function: |
|
1. Firstly, connect ZG1583RUD to PC. Download the software from and get more details.
2. The data are preserved in “year” folder, the name of document is <Day>.CSV.
|
Method 2: Data is stored on Micro SD card, the device does not need to be connected with PC while logging. |
|
Download the software from and get more details |
|
1. Connect ZG1583RUD to PC and install the software in the same way as step 1 of Method 1.
2. Execute the software, and then click「Date Memory Device (DMD)time/day synchronizing with PC」from the「Setting」menu. A message will pop up when set date and time for ZG1583RUD successfully.
3. Disconnect with PC, and power on the ZG1583RUD by AC adapter in 5min. If the device is idle for more than 5min, the setting of Date and Time may go wrong.
4. ZG1583RUD begins to measure and log the CO2/Temp./RH on the SD card.
5. The data are preserved in “year” folder, the name of document is <Day>.CSV on the SD card. |
|
|
|
|
|
|
|
|
|
Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to |
|
draw your attention to read the warning and entire User Manual before using the product. These are important |
|
safety information and should be observed at all times. |
|
|
|
|
|
|
|
|
To ensure you receive the maximum benefit from using this product, please observe the follow guidelines. |
|
1. Cleaning— Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning agent, such |
|
as benzene, thinner or aerosols. |
|
2. Repair----Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local |
|
dealer or a qualified repairman if the product needs servicing. |
|
3. Air diffusion: The ventilation slots on the housing are designed for CO2 diffusion, so these ventilation slots |
|
should not be blocked. |
|
|
|
|
|
|
Method - Dual Beam NDIR |
|
|
Display - LCD Independent CO2, RH and Temperature readings |
|
|
Sample Method - Diffusion or flow through (50 ~200 ml/min) |
|
|
CO2 & Temperature & RH Specification: |
CO2 |
Measurement Range |
0-3,000 ppm display |
Display Resolution |
1ppm at 0~1,000ppm; 5ppm at 1,001~2,000ppm; 10ppm at 2,001~3,000ppm |
Accuracy |
Under 25°C: ±80 ppm or ±5% of reading (≦2000ppm); ±7% reading (>2000ppm) |
Repeatability |
±20 ppm @ 400ppm |
Temperature Dependence |
Typ. ±0.2% of reading per °C or ±2 ppm per °C, whichever is greater, referenced to 25°C |
Response Time |
About 2min for 63% of step change |
Warm-Up Time |
1 min. at 22°C |
Zone LED Display |
Green: <800ppm; Yellow: 800~1200ppm;Red: >1200ppm |
Temperature |
Temperature Range |
0°C to 50°C (32°F to 122°F) display |
Display Resolution |
0.1°C (0.1°F) |
Display Options |
°C/°F |
Accuracy |
±1°C( ±2°F) When the fan blows to the device directly, the accuracy of temperature is ±1.5 degC |
Response Time |
20-30 minutes (case must equalize with environment) |
RH |
Measurement Range |
20%-90% RH |
Display Resolution |
1%RH |
Accuracy |
±5%RH@23°C |
Response time |
<5 min for 63% of step change |
Operating & Storage condition |
Operating Temperature |
0°C to 50°C (32°F to 122°F) |
Humidity Range |
0 ~ 95% RH non-condensing |
Storage Temperature |
-20°C to 60°C( -4°F to 140°F) |
Data Logger |
Sampling Inteval |
5 seconds |
Internal Data Logger with RTC |
Default 16G Micro SD card, user can replace this card. |
Capacity |
Logging of CO2, RH, and temperature, can log more than 10 years if sampling interval = 5 seconds and Micro SD Card is default 16G. |
Setting and Reading |
User should set the date and real time at PC with ZG View software, then power on the ZG1583RUD in 5 min. |
Power Supply |
Power Supply |
USB or 5 VDC from external AC/DC adapter which is included
in package (Use specified AC adapter only) |
DC Output voltage |
5 VDC, 1000mA |
AC Input voltage & Frequency |
100 ~ 240 VAC, 0.2A 50 / 60 Hz |
Communication interface
( ZG1583RUD ) |
Version |
USB 2.0 low speed function |
OS |
Windows XP ,Windows 7 |
|
|
|
|
|
|
|
1. |
You can use ZG1583RUD on the table (please pull out the Housing Stand ) or hang it on the wall. |
2. |
Please note the following when hanging it on the wall. |
|
Choose a suitable location to install ZG1583RUD, fix the screws to the wall. Please see 「Dimension」 |
|
section to check the distance between the screws. |
|
|
|
|
|
|
|
|
|
Dimension:
Inch(mm) |
 |
|
|
|
|
|
Fault Codes & Troubleshooting Guide |
|
|
|
This section includes a list of Frequently Asked Questions for problems you may encounter with the ZG1583RUD CO2 Monitor. |
|
|
|
|
|
|
|
|
Kinds of Adapters for your option |
|
|
|
ACAeu |
|
including |
German、Italy ) |
|
|
|
including Singapore、 |
BS1363 ) |
|
|
|
|
|
|
|


 |
|
|
|
|
|
|
|
|
Dimensions: 137*99*30.35mm |
|
Weight : 185.3g |
|
Adaptor + Mini USB Cable Weight : |
|
U.S Type: 111.45g |
|
EU Type: 119.55g |
|
U.K Type: 123.55g |
|
A.U Type: 116.4g |
|
One Set Included: |
|
|
1 CO2 Monitor |
|
1 Power Adaptor |
|
|
1 User Manual |
|
1 White Box |
|
|
1 SD Card (16GB) |
|
1 PE Bag |
|
|
(Package CO2 Monitor & Power Adaptor) |
|
One Carton Included: |
|
|
Q'ty: 20pcs PaperBoxes |
|
|
White Box Size: 245*155*60mm |
|
|
|
Carton Size: |
|
 |
U.S / EU Type: 532*330*365mm; 2.26 Cube ft |
|
 |
U.K / AU Type: 525*330*365mm; 2.26 Cube ft |
|
|
|
|
N.W: |
|
 |
U.S Type Power Adaptor: 9.3kgs |
|
 |
EU Type Power Adaptor: 9.4kgs |
|
 |
U.K Type Power Adaptor: 9.5kgs |
|
 |
A.U Type Power Adaptor: 9.4kgs |
|
|
G.W: |
|
 |
U.S Type Power Adaptor: 10.9kgs |
|
 |
EU Type Power Adaptor: 11kgs |
|
 |
U.K Type Power Adaptor: 11.1kgs |
|
 |
A.U Type Power Adaptor: 11kgs |
|
|
|
|
|
|
|
|
|
|
|
|