ZG106 ZG1163 ZG1683R ZGkb301 ZGkb201 ZGw08VRC / ZGw08PR ZGw063 / ZGw063R / ZGw063RY ZG10U ZG Module
CO2 Regulations Measurement Specifications Application Competitive Advantage

Archives

Family Spec. Photos Manuals Catalogs News Release COCO / COC
 
Home  
About Us Quality System Products Support Know - How of Gas Monitor Where to buy Contact Us  
 
    Home > Products > Desktop > ZG1683R  
 
  Desktop
  ZG1163
  ZG1683R
  ZGkb301
  ZGkb201
  ZGw08VRC
  ZGw08PR
  ZGw063
  ZGw063R
  ZGw063RY
  ZG10U
ZG01
 
  ZG SERIES - ZG1683R  
 
General Introduction
ZG1683R 3 IN 1 CO2 Monitor
  (CO2+Temp.+RH Operating Instructions)

Features

LED Display
Warm-Up Time: 2 MIN. Using the MUTE function
Safety Instructions Caring for product
Specifications Dimension

Fault Codes & Troubleshooting Guide

Available Packages
3 LED Display:
 < 800 ppm  800~1200 ppm  > 1200 ppm
 
 
General Introduction
 
  需要有一個值。
Indoor Air Quality (IAQ) is measure for the quality of air in interiors, the comfortable indoor environmental quality can make people feel fresh, work efficiency and good for the health. The CO2 concentration is the important factor of good indoor air quality. People breath in oxygen and breath out CO2, nowadays people often close the windows to avoid noise and enjoy the comfort living and working environment provided by air-conditioning systems, which results in the fact that the indoor concentration of CO2 is far higher than outdoor average. With the high CO2 concentration and non- proper ventilation, people will feel headaches, dull, drowsiness, lose of concentration and correspond to the high levels of dust, chemicals and bacteria in the air.
 
 
ZG1683R 3 IN 1 CO2 Monitor (CO2+Temp.+RH) Operating Instructions
 
 
 

ZG1683R CO2 monitor is smart, compact and easy-to-use. In addition to measuring the CO2 concentration,

  ZG1683R can also measure the ambient temperature and the relative humidity (CO2+Temp. +RH).
  This product is developed to detect the presence of CO2 in ambient air and help people to take care of Indoor
Air Quality. ZG1683R can be widely used in the office building, school, exhibition hall, shopping mall, meeting
  room, fitness center, restaurant and other public places where personal comfort, healthy is important. 
 
 
Features
 
 
NDIR technology to improve the long term stability
Measure CO2, Temperature and Relative Humidity
3 LED display shows the current Indoor Air Quality
Press “MUTE“ for alarm on/off
Built in the LCD Backlight for easy reading in the dark
 
 
LED Display
 
 
  1.Green LED Display (<800ppm)
  2.Yellow LED Display (800-1200ppm)
  3.Red LED Display  (>1200ppm)
  4.Mute Button
  5.Power Inlet
  5.Screw Position
  EMC/RFI
 

Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of

  approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
  Note: Under the electromagnetic field of 3V/m, the reading will not meet the specification.
 
 

Warm-Up Time: 2 MIN.

 
 
  1.2 min. warm-up time when first time power.
2.The LCD shows 4 bars with 1sec blank cycle during
warm-up
3. The MUTE button is disabled during warm-up
  4.The device shows the CO2 reading after warm-up
 
 

Using the MUTE function:

 
 
  1. Press MUTE button to select buzzer on/off.
Note: The device setting with alarm is buzzer on when
power on first time, user can set the alarm on/off under
MUTE function.
   
 
 
  Safety InstructionsCaring for product
 
 
  Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to
 

draw your attention to read the warning and entire User Manual before using the product. These are important

  safety information and should be observed at all times.
 
 
  Caring for product
 
 
 

To ensure you receive the maximum benefit from using this product, please observe the follow guidelines.

 

1. Cleaning— Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning agent, such

  as benzene, thinner or aerosols.
 

2. Repair----Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local

 

dealer or a qualified repairman if the product needs servicing.

  3. Air circulation---The vents allow the air circulation liquid for measurement of the CO2 concentration and the
  ventilation should not be blocked.
 
 
Specifications
 
  Method - NDIR  
  Display - LCD  Independent CO2, RH and Temperature readings  
 

Sample Method - Diffusion or flow through (50 ~200 ml/min)

 
 

CO2 & Temperature & RH Specification:

CO2 Measurement Range 0-3,000 ppm display
Display Resolution 1ppm at 0~1,000ppm; 5ppm at 1,001~2,000ppm; 10ppm at 2,001~3,000ppm
Accuracy Under 25°C: ±80 ppm or ±5% of reading (≦2000ppm); ±7% reading (>2000ppm)
Repeatability ±20 ppm @ 400ppm
Temperature Dependence Typ. ±0.2% of reading per °C or ±2 ppm per °C, whichever is greater, referenced to 25°C
Response Time About 2min for 63% of step change
Warm-Up Time 2 min. at 22°C
Zone LED Display Green: <800ppm; Yellow: 800~1200ppm;Red: >1200ppm
Temperature Temperature Range 0°C to 50°C (32°F to 122°F) display
Display Resolution 0.1°C (0.1°F)
Display Options °C/°F
Accuracy ±1°C( ±2°F) When the fan blows to the device directly, the accuracy of temperature is + / -1.5 degC
Response Time 20-30 minutes (case must equalize with environment)
RH Measurement Range 20%-90% RH
Display Resolution 1%RH
Accuracy ±5%RH@23°C
Response time <5 min for 63% of step change
Operating & Storage condition Operating Temperature 0°C to 50°C (32°F to 122°F)
Humidity Range 0 ~ 95% RH non-condensing
Storage Temperature -20°C to 60°C( -4°F to 140°F)
Power Supply Power Supply USB or 5 VDC from external AC/DC adapter which is included
in package (Use specified AC adapter only)
DC Output voltage 5 VDC, 1000mA
AC Input voltage & Frequency 100 ~ 240 VAC, 0.2A  50 / 60 Hz
 
 
Dimension
 
 
  Dimension:
Inch(mm)
 
 

Fault Codes & Troubleshooting Guide

 
 
This section includes a list of Frequently Asked Questions for problems you may encounter with the ZG1683R CO2 Monitor.
Fault Icon Description of the fault Suggested Actions
The ambient temperature has exceeded the operating temperature range 0°C to 50°C (32°F to 122°F) This error will clear when the temperature returns to the range between 0°C to 50°C (32°F to 122°F).
EEPROM System Problem

Please reconnect AC adapter to ZG1683R CO2 Monitor.
If the “Err5, Err6” still appears,
please contact the Service
Department for further assistance.

 
 
 
 

Available Packages

 
 
  ZG1683R(U.S Spec. Power Adaptor)
  Dimensions: 137*99*28mm
  Weight (including batteries): 186g
  One Set Included:
 
1 CO2 Monitor
1 Power Adaptor
 
1 User Manual
1 White Box
 
1 PE Bag ( Package Power Adaptor)
  One Carton Included:
 
Q'ty: 20pcs PaperBoxes
 
White Box Size: 245*155*60mm
 
Carton Size: 525*334*372mm
  N.W: 8.6 kgs
  G.W: 10.3 kgs
  ZG1683R(Europe Spec. Power Adaptor)
  Dimensions: 137*99*28mm
  Weight (including batteries): 186g
  One Set Included:
 
1 CO2 Monitor
1 Power Adaptor
 
1 User Manual
1 White Box
 
1 PE Bag ( Package Power Adaptor)
  One Carton Included:
 
Q'ty: 20pcs PaperBoxes
 
White Box Size: 245*155*60mm ;2.30Cube ft
 
Carton Size: 525*334*372mm ; 2.30Cube ft
  N.W: 9.1 kgs
  G.W: 10.8 kgs
 
 

TOTAL: